What was found
FORWARD UTILITY AREA FLOOR SUPPORT, Y-1292 BETWEEN FRAMES 16-20 UPPER FLANGE HAS CORROSION. BLENDED CORROSION IAW SRM 51-74-00. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-15, FIG 101. REMOVED FLOOR SUPPORT IAW SRM 51-42-11. LOCATED & DRILLED NEW FLOOR SUPPORT IAW SRM 51-44-11. INSTALLED NEW FLOOR SUPPORT IAW TRM 53-21-01.