What was found
AFT UTILITY AREA FLOOR SUPPORT Y-765 BETWEEN FRAMES 64-66 HAS CORROSION. BLENDED AREA IAW SRM 51-74-00. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-14, FIG 102. R & R FLOOR SUPPORT IAW SRM 51-42-11 & TRM 53-21-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT UTILITY AREA FLOOR SUPPORT Y-765 BETWEEN FRAMES 64-66 HAS CORROSION. BLENDED AREA IAW SRM 51-74-00. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-14, FIG 102. R & R FLOOR SUPPORT IAW SRM 51-42-11 & TRM 53-21-01.