What was found
AFT UTILITY AREA STRINGER 23R BETWEEN FRAMES 69-70, SHEAR PLATE UPPER SURFACE HAS CORROSION. BLENDED AREA IAW SRM 51-74-00. NO ESTABLISH LIMITS FOUND IN SRM 53-41-14, TABLE 101. R & R SHEAR PLATE IAW SRM 51-42-11 & DWG D53474180.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT UTILITY AREA STRINGER 23R BETWEEN FRAMES 69-70, SHEAR PLATE UPPER SURFACE HAS CORROSION. BLENDED AREA IAW SRM 51-74-00. NO ESTABLISH LIMITS FOUND IN SRM 53-41-14, TABLE 101. R & R SHEAR PLATE IAW SRM 51-42-11 & DWG D53474180.