What was found
AFT UTILITY AREA FLOOR SUPPORT Y-1292 BETWEEN FRAMES 66 - 68 UPPER FLANGE HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00 AND FOUND TO BE OUT OF LIMITS IAW SRM 53-00-14. R & R FLOOR SUPPORT IAW SRM 51-42-11 & TRM 53-21-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT UTILITY AREA FLOOR SUPPORT Y-1292 BETWEEN FRAMES 66 - 68 UPPER FLANGE HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00 AND FOUND TO BE OUT OF LIMITS IAW SRM 53-00-14. R & R FLOOR SUPPORT IAW SRM 51-42-11 & TRM 53-21-01.