What was found
AFT UTILITY AREA FLOOR SUPPORT Y765 BETWEEN FRAMES 64-66 UPPER FLANGE & HARDPOINT HOLES CORRODED. BLENDED AREA IAW SRM 51-74-00. FOUND OUT OF LIMIT IAW SRM 53-00-14, FIG 102. R & R FLOOR SUPPORT IAW SRM 51-42-11 & DWG D53472815.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT UTILITY AREA FLOOR SUPPORT Y765 BETWEEN FRAMES 64-66 UPPER FLANGE & HARDPOINT HOLES CORRODED. BLENDED AREA IAW SRM 51-74-00. FOUND OUT OF LIMIT IAW SRM 53-00-14, FIG 102. R & R FLOOR SUPPORT IAW SRM 51-42-11 & DWG D53472815.