What was found
FLOORBEAM AT BS 377 HAS CORROSION ON EDGE AND UPPER SURFACE FROM LBL 7 TO RBL 6. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51, FIG 101, DETAIL III, REPAIRED IAW SRM 53-00-51, REPAIR 10.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBEAM AT BS 377 HAS CORROSION ON EDGE AND UPPER SURFACE FROM LBL 7 TO RBL 6. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51, FIG 101, DETAIL III, REPAIRED IAW SRM 53-00-51, REPAIR 10.