What was found
DURING INSPECTION, FOUND AFT WET AREA, BS 947.5 +4, LBL 42-52, WL 208 FLOOR SUPPORT UPPER SURFACE IS CORRODED. MAINTENANCE R & R FLOOR SUPPORT, IAW SRM 51-40-02 AND DWG 147A5676, 53-70-51, 51-40-05, AMM 51-21-91.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND AFT WET AREA, BS 947.5 +4, LBL 42-52, WL 208 FLOOR SUPPORT UPPER SURFACE IS CORRODED. MAINTENANCE R & R FLOOR SUPPORT, IAW SRM 51-40-02 AND DWG 147A5676, 53-70-51, 51-40-05, AMM 51-21-91.