What was found
AFT CARGO, FLOOR SUPPORT CORRODED BS 1500-1520, RBL 7. REMOVED CORROSION IAW SRM 53-00-53 ALLOWABLE DAMAGED NOTE C, DETAIL V, FOUND TO BE OUT OF LIMITS. REMOVED FLOOR SUPPORT IAW ERA 332525-14MA STEP 1, NDT INSPECTION, NO FURTHER DAMAGE NOTED. FABRICATED REPAIR ANGLE ,TREATED AND PRIMED IAW ERA 332525-14MA, STEPS 4 AND 5. INSTALLED REPAIR ANGLE IAW ERA 332525-14MA, STEP 6.