What was found
DURING INSPECTION, FOUND CRACK INDICATIONS IN NINE OF THE SIXTEEN FASTENER HOLES COMMON TO THE LONGITUDINAL FLOOR SUPPORT SPLICE STRAP AT BS 727B. REPAIRED IAW ERA 520074-14 REV ORIGINAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND CRACK INDICATIONS IN NINE OF THE SIXTEEN FASTENER HOLES COMMON TO THE LONGITUDINAL FLOOR SUPPORT SPLICE STRAP AT BS 727B. REPAIRED IAW ERA 520074-14 REV ORIGINAL.