What was found
FLOORBEAM HAS CORROSION AROUND AND IN FASTENER HOLES BS 1640 LBL 10-RBL10. REMOVED CORROSION, FABRICATED REPAIR AND INSTALLED IAW SRM 53-00-51, 51-40-02 AND 51-20-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBEAM HAS CORROSION AROUND AND IN FASTENER HOLES BS 1640 LBL 10-RBL10. REMOVED CORROSION, FABRICATED REPAIR AND INSTALLED IAW SRM 53-00-51, 51-40-02 AND 51-20-01.