What was found
FWD CARGO BAY AFT WALL LOWER SUPPORT ANGLE CORRODED, BS 845 RBL 20-LBL 20. REMOVED CORROSION, FOUND OUT OF LIMITS. REMOVED LOWER SUPPORT ANGLE AND FABRICATED REPAIR. PRIMED AND TREATED IAW SRM 51-10-02, SRM 53-00-53, SRM 51-40-02 AMM 51-21-04-107-017 PG 1-6, AMM 51-21-10-377-003 PGS 1-3 & DWG 453N814-16.