What was found
NR 2 PYLON HYDRAULIC DISCONNECT PANEL DOUBLER CRACKED AT LOWER END BELOW LOWER AFT HYDRAULIC FEED THRU HOLE. REMOVED AND REPLACED DOUBLER IAW SRM 51-40-02 PG 6 & 7
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NR 2 PYLON HYDRAULIC DISCONNECT PANEL DOUBLER CRACKED AT LOWER END BELOW LOWER AFT HYDRAULIC FEED THRU HOLE. REMOVED AND REPLACED DOUBLER IAW SRM 51-40-02 PG 6 & 7