What was found
CORROSION ON FLOORBEAM UPPER SURFACE BS 1640, LBL 10 -RBL 10. REMOVED CORROSION IAW SRM 51-10-02, PAR 15 & 51-20-01 PAR 4, UT INSPECTED AREA IAW NDTM PAR 4, 51-00-10. FOUND AREA TO BE OUT OF LIMITS IAW SRM 53-00-51 A1 & 53-60-51-I2. CUT OUT 8 EA DAMAGE AREAS FROM FLOORBEAM & FABRICATED REPAIR PARTS. INSTALLED REPAIR PARTS IAW SRM 53-00-51, REP 5 51-21-01, PARA 4 & FIG 1 AND AMM 51-21-00-377.