What was found
CORROSION OUT OF LIMITS ON INTERCOSTAL BELOW DOOR FRAME WEB, BS 1183 AND 1193 AT AFT CARGO BAY. INTERCOSTALS REMOVED IAW SRM 51-30-2-51-30-5. NEW INTERCOSTALS INSTALLED IAW SRM 51-30-2 - 51-30-5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.