What was found
ON REMOVAL OF FUSELAGE SKIN, LT BS 590-660 DISCOVERED STR 16L DENTED ON LOWER FLANGE AT STA 598-605. DENT ON STR 16L LWR FLANGE STA 598-605 MEASURED A=1.0", Y=.050" A/Y=20. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-03, ALLOWABLE DAMAGE 1, PG 2, FIGURE 101, DETAIL III. REPAIRED STR 16L FROM STA 570-612 IAW SRM 53-00-03, REPAIR 1, FIG 201 AS PERMANENT.