What was found
FLOORBEAM FROM +YA TO +YB AT FRAME 73, FOUND CORRODED. CORROSION REMOVED IAW SRM 51-74-00. FOUND EXCEEDED LIMITS IAW SRM 53-41-14, FIG 103. REPLACED FLOORBEAM IAW SRM 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBEAM FROM +YA TO +YB AT FRAME 73, FOUND CORRODED. CORROSION REMOVED IAW SRM 51-74-00. FOUND EXCEEDED LIMITS IAW SRM 53-41-14, FIG 103. REPLACED FLOORBEAM IAW SRM 51-42-11.