What was found
CREW NOTED THAT DURING LEVEL OFF AT FL240, THE FLOW LIGHT ILLUMINATE AND THE CABIN LOST PRESSURIZATION. INITIATED A RAPID DESCENT, PAX OXYGEN MASKS DEPLOYED AUTOMATICALLY, AND LANDED SAFELY. LT PACK FAILED. MAINTENANCE FOUND LT PACK ICE SCREEN AND WATER SEPARATOR OBSCURED WITH ICE. WATER DRAIN LINE CLEARED, LT WATER SEPARATOR REPLACED, AND ASSOCIATED TEMPERATURE CONTROL VALVE REPLACED.