What was found
ELONGATED HOLES ON WEB, ANGLES AND FITTING BETWEEN XH=27 AND XHS=97 ALSO ON PRODUCTION DOUBLER BETWEEN XH=27 AND XHS=41 AT RT HORIZONTAL STABILIZER REAR SPAR. DAMAGED WEB , ANGLES AND FITTING AND DOUBLER REMOVED IAW SRM 51-30-1, 51-30-2 AND 51-30-5, FABRICATED IAW DWG 9918401, REV "DC" AND TREATED AND PAINTED IAW SRM 51-10-3, PAR 14/21. NEW WEB, DOUBLER , ANGLES AND FITTING WERE INSTALLED IAW DWG 9918401, REV "DC" AND SRM 51-30-1, 51-30-2, AND 51-30-5 G.