As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT UTILITY AREA FLOOR SUPPORT -Y1292 BETWEEN FRAMES 66-68 UPPER FLANGE HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00. FOUND TO BE OUT OF LIMITS IAW TRM 51-41-15 PAR. 3D. R & R FLOOR SUPPORT IAW TRM 53-21-00 & SRM 51-42-11 AND SRM 51-44-11.