What was found
DURING INSPECTION, FOUND AFT WET AREA, BS 951 - 962, RBL 50, FLOOR SUPPORT UPPER SURFACE CORRODED. R & R FLOOR SUPPORT IAW DWG 147A5650, REV E.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND AFT WET AREA, BS 951 - 962, RBL 50, FLOOR SUPPORT UPPER SURFACE CORRODED. R & R FLOOR SUPPORT IAW DWG 147A5650, REV E.