What was found
MAIN CABIN FLOOR FRAME, BS 880, RBL 50 HAS FASTENER HOLE WITH DEEP GOUGE. ACCOMLISHED REPAIR IAW SRM 53-00-51 REP. 1 PG 201 FIG 201 PARA 17.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN CABIN FLOOR FRAME, BS 880, RBL 50 HAS FASTENER HOLE WITH DEEP GOUGE. ACCOMLISHED REPAIR IAW SRM 53-00-51 REP. 1 PG 201 FIG 201 PARA 17.