What was found
FOUND SKIN DAMAGE AT RT SIDE OF ACFT STRINGER 17, STATION 382. BURNISHED GOUGE IAW SRM 53-00-01. HFEC INSPECTED BURNISHED AREA IAW SRM 53-00-01. NO CRACKS INDICATED. FINISHED REPAIR SRM 53-00-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND SKIN DAMAGE AT RT SIDE OF ACFT STRINGER 17, STATION 382. BURNISHED GOUGE IAW SRM 53-00-01. HFEC INSPECTED BURNISHED AREA IAW SRM 53-00-01. NO CRACKS INDICATED. FINISHED REPAIR SRM 53-00-01.