What was found
FLOOR SUPPORT BETWEEN Y1959, FRAME 13A AND 18 FOUND CORRODED. CORROSION REMOVED IAW SRM 51-74-00. FOUND OUT OF LIMITS IAW SRM 53-11-15, FIG 101. FLOOR SUPPORT R & R IAW SRM 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR SUPPORT BETWEEN Y1959, FRAME 13A AND 18 FOUND CORRODED. CORROSION REMOVED IAW SRM 51-74-00. FOUND OUT OF LIMITS IAW SRM 53-11-15, FIG 101. FLOOR SUPPORT R & R IAW SRM 51-42-11.