What was found
FLOOR SUPPORT AT INBD OF -450, FRAMES 76 AND 77 FOUND CORRODED. CORROSION REMOVED IAW SRM 51-74-00. FOUND OUT OF LIMITS IAW SRM 53-41-14, FIG 103. FLOOR SUPPORT R & R IAW SRM 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.