What was found
FWD CARGO BAY BS 845 WALL LOWER ATTACH ANGLE IS CORRODED BETWEEN LBL 12-24. REMOVED DAMAGED ANGLE IAW SRM 51-40-02, FABRICATED NEW ANGLE IAW SRM 51-30-01 AND DWG: 453N1151 REV.F, INSTALLED NEW ANGLE IAW SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CARGO BAY BS 845 WALL LOWER ATTACH ANGLE IS CORRODED BETWEEN LBL 12-24. REMOVED DAMAGED ANGLE IAW SRM 51-40-02, FABRICATED NEW ANGLE IAW SRM 51-30-01 AND DWG: 453N1151 REV.F, INSTALLED NEW ANGLE IAW SRM 51-40-02.