What was found
DURING INSPECTION, FOUND CORROSION ON FLOOR SUPPORT -Y765 BETWEEN FRAMES 64 TO 66+5. REPLACED FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53472831.