What was found
DURING INSPECTION, FOUND CORROSION ON LOWER CORNER FITTING LOCATION IN FRAME 16 AT STR 23R. REPLACED LOWER CORNER FITTING LOCATION IN FR16 AT LEVEL OF STR 23R IAW SRM 51-72-11 AND DWG 53112109.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND CORROSION ON LOWER CORNER FITTING LOCATION IN FRAME 16 AT STR 23R. REPLACED LOWER CORNER FITTING LOCATION IN FR16 AT LEVEL OF STR 23R IAW SRM 51-72-11 AND DWG 53112109.