What was found
INNER ANGLE HAS EXFOLIATION CORROSION ON UPPER SURFACE FROM BS 1600-1630, LT MAIN CABIN. REMOVED CORROSION, BS 1600-1630, CORROSION FOUND TO BE WITHIN LIMITS, BS 1600-1620, CORROSION OUT OF LIMITS BS 1630. INSTALLED PERMANENT REPAIR IAW E/RA 521543-14, REV ORIGINAL CORROSION REMOVAL ACCOMPLISHED IAW SRM 53-60-13.