What was found
DURING INSPECTION, FOUND FORWARD GALLEY WET AREA FLOOR SUPPORT LT SIDE BS 312-328, LBL 12 CORRODED ON UPPER SURFACE AT NUTPLATE HOLES. MAINTENANCE R & R FLOOR SUPPORT IAW SRM 51-40-02 PG 1-10 AND DWG 141A5400.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND FORWARD GALLEY WET AREA FLOOR SUPPORT LT SIDE BS 312-328, LBL 12 CORRODED ON UPPER SURFACE AT NUTPLATE HOLES. MAINTENANCE R & R FLOOR SUPPORT IAW SRM 51-40-02 PG 1-10 AND DWG 141A5400.