What was found
DURING INSPECTION, FOUND AFT GALLEY WET AREA FLOOR SUPPORT RT SIDE BS 947-967, RBL 51 CORRODED AROUND NUTPLATE HOLES. MAINTENANCE REPLACED FLOOR SUPPORT IAW DWG 147A5660, REV. A AND SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND AFT GALLEY WET AREA FLOOR SUPPORT RT SIDE BS 947-967, RBL 51 CORRODED AROUND NUTPLATE HOLES. MAINTENANCE REPLACED FLOOR SUPPORT IAW DWG 147A5660, REV. A AND SRM 51-40-02.