What was found
DURING INSPECTION, FOUND R2 DOOR CUTOUT LOWER SILL CREASE BEAM INNER ANGLE CORRODED ON UPPER SURFACE. MAINTENANCE REPLACED CREASE BEAM IAW SRM 51-40-02, PG1-9,33 FIG.8, PARA 4,7 AND DWG 147A8540, REV B.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND R2 DOOR CUTOUT LOWER SILL CREASE BEAM INNER ANGLE CORRODED ON UPPER SURFACE. MAINTENANCE REPLACED CREASE BEAM IAW SRM 51-40-02, PG1-9,33 FIG.8, PARA 4,7 AND DWG 147A8540, REV B.