What was found
NR 2 PYLON FWD UPPER SPAR FITTING ATTACH BUSHING EDGE SEALANT FOUND CRACKED. FABRICATED AND INSTALLED IAW SRM 54-53-90.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NR 2 PYLON FWD UPPER SPAR FITTING ATTACH BUSHING EDGE SEALANT FOUND CRACKED. FABRICATED AND INSTALLED IAW SRM 54-53-90.