What was found
LT SIDE OVERWING EXIT EMERGENCY LIGHTS ARE INOPERATIVE. FOUND GROUND PIN "GD44007-DC" CORRODED. REPLACED GROUND PIN IN GROUNDING BLOCK. LIGHT CHECKED GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LT SIDE OVERWING EXIT EMERGENCY LIGHTS ARE INOPERATIVE. FOUND GROUND PIN "GD44007-DC" CORRODED. REPLACED GROUND PIN IN GROUNDING BLOCK. LIGHT CHECKED GOOD.