What was found
DURING INSPECTION, FOUND CORROSION ON SHEAR TIE LOCATED IN THE FWD CARGO BAY AT FRAME 31 BETWEEN STRINGERS 39-40R. REPLACED SHEAR TIE IAW SRM 51-72-11 AND DWG D53231623.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND CORROSION ON SHEAR TIE LOCATED IN THE FWD CARGO BAY AT FRAME 31 BETWEEN STRINGERS 39-40R. REPLACED SHEAR TIE IAW SRM 51-72-11 AND DWG D53231623.