What was found
DURING INSPECTION, FOUND CORROSION ON FLOOR SUPPORT -Y765 BETWEEN FRAMES 66+5-70. REPLACED FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53472816.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND CORROSION ON FLOOR SUPPORT -Y765 BETWEEN FRAMES 66+5-70. REPLACED FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53472816.