DURING INSPECTION, FOUND CORROSION ON FLOOR SUPPORT AT FRAME 67+18, Y765. REPLACED FLOOR SUPPORT BETWEEN FRAMES 66-70 IAW SRM 51-72-11 AND DWG 53472000.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND CORROSION ON FLOOR SUPPORT AT FRAME 67+18, Y765. REPLACED FLOOR SUPPORT BETWEEN FRAMES 66-70 IAW SRM 51-72-11 AND DWG 53472000.