What was found
CORROSION ON FLOORBEAM FRAME 16, LEVEL Y765. REWORKED IAW SRM 51-74-00. FOUND WITHIN LIMITS IAW SRM 53-11-15, PARA 4.B, FIG 106 AND APPLIED PROTECTIVE TREATMENT IAW SRM 51-21-11 AND SRM 51-23-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON FLOORBEAM FRAME 16, LEVEL Y765. REWORKED IAW SRM 51-74-00. FOUND WITHIN LIMITS IAW SRM 53-11-15, PARA 4.B, FIG 106 AND APPLIED PROTECTIVE TREATMENT IAW SRM 51-21-11 AND SRM 51-23-11.