What was found
NON ROUTINE CHECK, CORROSION FOUND ON PREVIOUS REPAIR ON MID CARGO BAY LOWER DOOR FRAME BEAM BETWEEN BS 648-662. REPAIR REMOVED IAW SRM 51-30-5, NEW SPACER REPAIR WAS FABRICATED IAW SRM 53-05, FIG 123, TREATED AND PAINTED IAW SRM 51-10-3, PAR 21 AND 14, FABRICATED NUT STRIP IAW SRM 53-05, FIG 23, TREATED AND PAINTED IAW SRM 51-10-3, PAR 21,14. NEW SPACER REPAIR AND NUT STRIP INSTALLED IAW SRM 51-30-5.