CABIN FLOOR CUSP WEB RT CORRODED AT UPSIDE BETWEEN STA 694-714. FOUND CORROSION OUT OF LIMITS. CUTOUT DAMAGE. FABRICATED FILLER AND REPAIR SPLICES IAW SRM 53-20-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CABIN FLOOR CUSP WEB RT CORRODED AT UPSIDE BETWEEN STA 694-714. FOUND CORROSION OUT OF LIMITS. CUTOUT DAMAGE. FABRICATED FILLER AND REPAIR SPLICES IAW SRM 53-20-02.