What was found
FLOOR SUPPORT CORRODED BS 160 BL 0. FOUND OUT LIMITS IAW SRM 53-00-01, FIG 3, VOL I, REMOVED AND REPLACED FLOOR SUPPORT IAW SRM 51-30-02, DWG 9936534, SRM 51-10-03, PAR 14 AND 21, VOL 2, AMM 51-00-01, AND INSTALLED IAW DWG 9936534.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR SUPPORT CORRODED BS 160 BL 0. FOUND OUT LIMITS IAW SRM 53-00-01, FIG 3, VOL I, REMOVED AND REPLACED FLOOR SUPPORT IAW SRM 51-30-02, DWG 9936534, SRM 51-10-03, PAR 14 AND 21, VOL 2, AMM 51-00-01, AND INSTALLED IAW DWG 9936534.