What was found
CORROSION ON RT FUEL TANK ACCESS PANEL 1436C AT COUNTERSINK AREA. CORROSION REMOVED AND FOUND OUT OF LIMITS. ACCESS PANEL WAS REPAIRED IAW SRM 51-22-2A, CONDITION II. REPAIR BUSHINGS WERE FABRICATED IAW SRM 51-22-2A, PAR 6 CONDITION II, B, 4. NEW BUSHINGS AND REWORKED AREA WERE TREATED IAW SRM 51-10-3, PAR 21. REPAIR BUSHINGS INSTALLED IAW SRM 51-22-2A.