What was found
CORROSION ON RT FUEL TANK ACCESS PANEL 1470C. CORROSION REMOVED AND FOUND OUT OF LIMITS. ACCESS PANEL REMOVED IAW SRM 51-22-2A CONDITION II. BUSHING FABRICATED" AND COUNTERSUNK IAW SRM 51-22-2A PAR NR 6. NEW BUSHING AND AREA WERE TREATED IAW SRM 51-10-3, PAR. 21 AND NEW BUSHING AND AREA WERE TREATED IAW SRM 51-10-3, PAR. 21 AND NEW BUSHING WAS INSTALLED IAW SRM 51-22-2A, PAR 6.