What was found
STATIC DISCHARGE ON SKIN AT BS 1195 AND 2.5 INCHES ABOVE STRINGER 9L. DRILLED OUT DAMAGE AND INSPECTED WITH 10X MAGNIFICATION. TREATED, PAINTED AND INSTALLED BLIND RIVET IAW SRM 53-00-01, FIG 201.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STATIC DISCHARGE ON SKIN AT BS 1195 AND 2.5 INCHES ABOVE STRINGER 9L. DRILLED OUT DAMAGE AND INSPECTED WITH 10X MAGNIFICATION. TREATED, PAINTED AND INSTALLED BLIND RIVET IAW SRM 53-00-01, FIG 201.