What was found
CORROSION FOUND ON FLAP HINGE FITTING, XRS=267 RT WING T/E. HINGE REPLACED IAW AMM 57-40-01 AND 27-50-02 AND HINGE BRACKET AND ACTUATOR REMOVED AND INSTALLED IAW AMM 27-52-02, LEAK CHECKED ACTUATOR WAS PERFORMED, NO LEAKS FOUND.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND ON FLAP HINGE FITTING, XRS=267 RT WING T/E. HINGE REPLACED IAW AMM 57-40-01 AND 27-50-02 AND HINGE BRACKET AND ACTUATOR REMOVED AND INSTALLED IAW AMM 27-52-02, LEAK CHECKED ACTUATOR WAS PERFORMED, NO LEAKS FOUND.