What was found
FASTENER AT BS 977, S6L LIGHTNING BURNED. REMOVED FASTENER CLEANED AREA INSPECTED WITH 10X MAGNIFICATION. REMOVED, TREATED, PAINTED AND INSTALLED BLIND RIVET IAW SRM 53-00-01, FIG 201.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FASTENER AT BS 977, S6L LIGHTNING BURNED. REMOVED FASTENER CLEANED AREA INSPECTED WITH 10X MAGNIFICATION. REMOVED, TREATED, PAINTED AND INSTALLED BLIND RIVET IAW SRM 53-00-01, FIG 201.