What was found
CRACK ON INSIDE BRACKET OF DORSAL FIN AREA, BS 1425, BETWEEN STR 1 AND 2R. REMOVED ANGLE, FABRICATED, HEAT TREATED TO T6 CONDITION TREATED, PRIMED & INSTALLED ANGLE AT F/S 1425, BETWEEN STR 1-2R ALL IAW SRM 51-30-2, 51-30-05, 51-10-3, DWG 5912188, REV BD.