What was found
CRACK ON INTERNAL DOUBLER AT LOWER AFT DOOR JAMB CORNER OF THE FWD CARGO COMPARTMENT AT FS, Y=423.5 BETWEEN LONGS 27-28RH, SM, ZONE 051, CARD 03. SUMMARY: REPAIR WAS ACCOMPLISHED IAW ER/A 521210-14AD, REV ORIGINAL AND ETI-88-14-032, REV 4. THIS REPAIR IS APPROVED AS TIME-LIMITED UNTIL DAMAGE TOLERANCE EVACUATION IS ACCOMPLISHED WITHIN 24 MONTHS, FRAME AS REQUIRED BY 14 CFR 25.571 AND 14 CFR 26 SUB PART IAW ER/A 521210-14AD, REV ORIGINAL SECTION II. RII COMPLETED, ASSOCIATED ER/A 00-521210 ADDED FOR AC 0964.