What was found
DURING CHEM-MILL INSPECTION. FOUND FASTENER AT S4R, BS 360 DAMAGED WITH EVIDENCE OF LIGHTNING STRIKE. REMOVED DAMAGE AND INSPECTED, NO CRACKS FOUND , AND INSTALLED REPAIR IAW SRM 53-00-01.