What was found
AFTER REMOVAL OF RIVETS, PERFORMED VISUAL INSPECTION ON ADJACENT AREA AND FOUND CORROSION ON CLEAT AT FRAME 33 BETWEEN STRINGERS 41-42R IN FWD CARGO BAY. REPLACED CLEAT IAW SRM 51-72-11 AND DRAWING D53231582.