What was found
CORROSION FOUND ON FLOOR SUPPORT BETWEEN FRAMES 20 - 24 -Y189. REPLACED FLOOR SUPPORT IAW SRM A319 51-72-11 AND DRAWING D53111406.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND ON FLOOR SUPPORT BETWEEN FRAMES 20 - 24 -Y189. REPLACED FLOOR SUPPORT IAW SRM A319 51-72-11 AND DRAWING D53111406.